How to I change my beacon batteries?

RevlX beacons have a 2-3 year operational life. Look here to learn how to change the batteries.

Tools and parts. 
- Large phillips head screwdriver #4
- Small phillips head screwdriver #2
- 8 D-Cell batteries. We recommend using name brand batteries with recent purchase/manufacture dates. 

  1. First determine if the beacon batteries need to be replaced using this guide
  2. Locate the beacon in question. See this page to learn more about identifying beacons and antennas.
  3. Open the beacon housing using a large phillips head screwdriver. The beacon body will be attached to the housing lid. 
  4. If needed, you can remove the beacon antenna connection to gain more movement. 
  5. Using a smaller phillips head screwdriver, remove the two screws on the side of the beacon body. This will release the beacon body from the housing lid. 
  6. Remove the four screws on the back of the beacon housing. This will allow the beacon to open and reveal 8 D-cell batteries. 
  7. Replace all 8 batteries and reverse order to reassemble. 

Place holder for now. https://cdn.shopify.com/s/files/1/0481/4309/files/RadiusNetworks_RadBeacon_E8_June2019.pdf?125